| Sign In | Join Free | My disqueenfrance.com |
|
Brand Name : Zetron
Model Number : MIC300-VOC-H
Certification : CE, Atex, RohS, ISO
Place of Origin : China
MOQ : 1 piece
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 10000 set/month
Delivery Time : in stock
Packaging Details : paper box
product type : Gas Detector
Detection range : 0~1000, 2000, 5000, 10000ppm, 30%Vol, 100%Vol optional
explosive grade : Exd II CT6/DIP A20 TA, T6
protection level : IP66
material : aluminum alloy, surface anticorrosive paint sprayed
Warranty : 1 year
MIC300-VOC-H Online Toxic and Harmful Gas Detector



| Type | Fixed Gas Detector | ||||
| Allowable error | ≤±3% F.S (other or higher precision levels can be customized) | ||||
| Linearity | ≤±2% | Repeatability | ≤±2% | Uncertainty | ≤±2% |
| Response time | T90≤30 seconds | Recovery time | ≤30 seconds | ||
| Working environment | Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH (regular) | ||||
| Power supply reference | 24V, 2.1A is possible to drive 40 units of toxic gas detector, or 15 units of flammable, infrared gas detector. | ||||
| Working method | Fixed type installation, online detection, diffusion type measurement | ||||
| Protection level | IP65 | ||||
| Explosion-proof mark | ExdⅡCT6, certificate number: CNEx15.1283 | ||||
| Exterior dimensions | 233×205×65mm (L×H×W) | ||||
| Weight | 1.0 Kg | ||||
| Standard accessories | Manual, qualification certificate, warranty card, outer packaging box | ||||
| Gases to be detected | Range | Accurancy | Resolution | Response time T90 |
| Ethylene ( C2 H4 ) | 0-100%LEL | <±2%(F.S) | 0.1%LEL | ≤30 seconds |
| Acetaldehyde | 0-10ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds |
| Ethanol ( C2 H6O ) | 0-100ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds |
| Methanol ( CH4O ) | 0-100ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds |
| Combustible gas ( EX ) | 0-100%LEL | <±2%(F.S) | 0.1%LEL | ≤10 seconds |
| Methane ( CH4 ) | 0-100%Vol | <±2%(F.S) | 0.1%Vol | ≤10 seconds |
| Oxygen gas ( O2 ) | 0-30%Vol | <±2%(F.S) | 0.01%Vol | ≤10 seconds |
| Nitrogen gas ( N2 ) | 0-100%Vol | <±2%(F.S) | 0.01%Vol | ≤10 seconds |
| Hydrogen gas ( H2 ) | 0-40000ppm | <±2%(F.S) | 1ppm | ≤30 seconds |
|
|
Zetron MIC300-VOC-H Fixed Gas Detector PID Light Ion High Precision VOC Images |